Website is intended for physicians
Search:
Всего найдено: 2

 

Abstract:

This article spotlights problems of diagnostic and treatment of rare vascular complication: false aneurysm of transplanted kidney artery We describe a case of successful treatment using stent-assisted aneurysm embolization. Our case is illustrated with ultrasound, computed tomography and angiographic images and 30-day follow-up data.

 

References

1.      Tomilina N., Bikbov B. Sostojanie zamestitel'noj terpapii pri hronicheskoj pochechnoj nedostatochnosti v Rossii v 1998-2011 gg. (po dannym registra Rossijskogo dializnogo obshhestva) [The status of substitutive therapy in chronic renal insufficiency in Russia in 1998-2011. (according to the register of the Russian Dialysis Society).]. Vestnik transplantologii i iskusstvennyh organov. 2015; 17(1):35-58 [In Russ].

2.      Streeter E.H., Little D.M., Cranston D.W. and Morris P.J. The urological complications of renal transplantation: a series of 1535 patients. BJU International. 2002; 90: 627634.

3.      Verstova A.I., Kokov L.S., Parhomenko M.V., Pinchuk A.V. Klinicheskij sluchaj jembolizacii lozhnoj anevrizmy arterii pochechnogo transplantata Materialy VII nauch.-obr. foruma 2015 g [Clinical case of embolization of a false aneurysm of an artery of a transplanted kidney.]. Rossijskij Jelektronnyj Zhurnal Luchevoj Diagnostiki = Russian Electronic Journal of Radiology (REJR). 2015; 5(2) Pril.:231-232[ In Russ].

4.      Matas A.J., Payne W.D., Sutherland DER, et al. 2,500 Living Donor Kidney Transplants: A Single-Center Experience. Annals of Surgery. 2001; 234(2):149-164.

5.      Orlic P., Vukas D., Curuvija D., Markic D., Merlak-Prodan Z., Maleta I., Zivcic-Cosic S., Orlic L., Blecich G., Valencic M., Spanjol J., Budiselic B. Pseudoaneurysm after renal transplantation. Acta Med Croatica. 2008; 62(1):86-9.

6.      Fujikata S., Tanji N., Iseda T., Ohoka H., Yokoyama M. Mycotic aneurysm of the renal transplant artery. Int J Urol. 2006;13: 820e3.

7.      Al-Wahaibi K.N., Aquil S., Al-Sukaiti R., Al-Riyami D., Al-Busaidi Q. Transplant Renal Artery False Aneurysm: Case Report and Literature Review. Oman Medical Journal. 2010; 25(4):306-310.

8.      Bracale U.M., Santangelo M., Carbone F., Del Guercio L., Maurea S., Porcellini M., Bracale G. Anastomotic pseudoaneurysm complicating renal transplantation:treatment options. Eur J Vasc Endovasc Surg. 2010 May; 39(5):565-8.

9.      Dimitroulis D., Bokos J., Zavos G., Nikiteas N.Karidis P., Katsaronis P., et al. Vascular complications in renal transplantation: a single-center experience in 1367 renal transplantations and review of the literature. Transplant Proc. 2009; 41:1609e14.

10.    Burkey S.H., Vazquez M.A., Valentine R.J. De novo renal artery aneurysm presenting 6 years after transplantation: a complication of recurrent arterial stenosis? J Vasc Surg. 2000; Aug;32(2):388-391 10.1067/mva.2000. 106943.

11.    McIntosh B.C., Bakhos C.T., Sweeney T.F., DeNa- tale R.W., Ferneini A.M. Endovascular repair of transplant nephrectomy external iliac artery pseudoaneurysm. Conn Med. 2005; Sep;69(8):465-466.

12.    Bracale U.M., Carbone F., del Guercio L., Viola D., D’Armiento F.P., Maurea S. et al. External iliac artery pseudoaneurysm complicating renal transplantation. Interact Cardiovasc Thorac Surg. 2009. Jun; 8(6):654-660 10.1510/icvts.2008.200386.

13.    Asztalos L., Olvaszto' S., Fedor R., Szabo' L., Bala 'zs G., Luka' cs G. Renal artery aneurysm at the anastomosis after kidney transplantation. Transplant Proc. 2006; 38:2915e8.

 

Abstract:

Article describes a case report of successful treatment of coronary artery perforation using handmade stent-graft, ex tempore made of coronary balloon and two bare-metal stents. Article also reports results of follow-up, including control angiography and optical coherence tomography 3 months later. 

 

References

1.     Ellis S.G., Ajluni S., Arnold A.Z., Popma J.J., Bittl J.A., Eigler N.L. et al. Increased coronary perforation in the new device era. Incidence, classification, management, and outcome. Circulation. 1994; 90(6):2725-30.

2.     Shirakabe A., Takano H., Nakamura S., Kikuchi A., Sasaki A., Yamamoto E. et al. Coronary perforation during percutaneous coronary intervention. Int Heart J. 2007; 48(1):1-9.

3.     Lansky A.J., Yang YM., Khan Y, Costa R.A., Pietras C., Tsuchiya Y et al. Treatment of coronary artery perforations complicating percutaneous coronary intervention with a polytetrafluoroethylene-covered stent graft. Am J Cardiol. 2006; 98(3): 370-4.

4.     Sarli B., Baktir A.O., Saglam H., Kurtul S., Dogan Y., Aring H. Successful Treatment of Coronary Artery Perforation with Hand-Made Covered Stent. Erciyes Med J. 2013; 35(3):164-6 • DOI: 10.5152/etd.2013.20.

5.     Copeland K.A., Hopkins J.T., Weintraub W.S., Rahman E. Long-term follow-up of polytetrafluoroethylene-covered stents implanted during percutaneous coronary intervention for management of acute coronary perforation. Catheter Cardiovasc Interv. 2012; 80(1):53-7.

 

 

ANGIOLOGIA.ru (АНГИОЛОГИЯ.ру) - портал о диагностике и лечении заболеваний сосудистой системы